-40%
ElCon Industrial Battery Charger TCCH-216-10 PFC1500
$ 158.37
- Description
- Size Guide
Description
ElCon Industrial Battery Charger TCCH-168-10 TCCH-216-10In Good Condition, Has Minor Outside Wear,
Originally Used on Selection 9 - 76 Cells, 266 - 277.4 to Charge Backup Battery,
Tested and Fully Operational
These waterproof ElCon Chargers are true power factor correction chargers capable of being programmed for just about any battery chemistry. This allows you to have the optimal charging algorithm for your particular pack of batteries whether you are using AGM, Gel, Flooded SLA, Ni-Cad, NiMH, Lithium or any other rechargeable battery that may come on to the market in the future.
Advantages
-Internal integrated PFC, no pollution to electric network, protect shocking on electric network from heavy current.
-Wide input voltage range AC85V~AC265V available for worldwide requirements, convenient for electric-network fluctuation and vehicles exportation.
-High with 93% above efficiency while only about 80% efficiency the traditional chargers can meet.
-Intelligent temperature compensation function in the charging process, preventing the damage to battery caused by charge-off or charge due, greatly extending the lifespan of the battery.
-Fully-sealed and water-proof, protecTCCH-192-06tion class IP65. Shock resistance treatment made inside makes vibration proof level up to SAEJ1378 that can fully meet the standard of automobile appliance usage.
-Available for various kinds batteries like Lead-Acid, LiFePO4 Battery etc., Flexible and programmable of the charging module. Memory to store 10 unique algorithms with ability to switch between algorithms.
-Available with CAN communication interface for BMS-controlled charging.
Technical Features
AC Input Voltage Range
AC85V~AC265V
AC Input Frequency
45~65 Hz
AC Power Factor
≥0.98
Full Load Efficiency
≥93%
Mechanical Shock &
Vibration Resistance Level
Conformance to
SAEJ1378 Standard
Environmental
Enclosure
IP65
Operating Temperature
-40
℃
~+55
℃
Storage Temperature
-40
℃
~+100
℃
Mechanical Dimension
s
35
2mm×175mm×139mm
Net Weight
6.33kg
LED Indicator
Red-Green flash
(one second interval)
Battery Disconnected
Red flash
(three seconds interval)
Repair Battery
Red flash
(one second interval)
<80% Charge Indicator
Yellow flash
(one second interval)
>80% Charge Indicator
Green flash
(one second interval)
100% Charge Indicator
Protection Features
1. Thermal Self-Protection: When the internal temperature of the charger exceeds 75℃, the charging current will reduce automatically. If exceeds 85℃, the charger will shutdown protectively. When the internal temperature drops, it will resume charging automatically.
2. Short-circuit Protection: When the charger encounters nexpected short circuit across the output, charging will automatically stop. When fault removes, the charger will re-start in 10 seconds.
3. Reverse Connection Protection: When the battery is polarity reversed, the charger will disconnect the internal circuit and the battery, the charging will stop and avoid been damaged
.
4.
Input Low-voltage Protection: When the input AC Voltage is lower than 85V, the charger will shutdown protectively and automatically resume working after the voltage is normal again.
Choice of Charging Curve (curve 1~10)
1. The LED will flash red several times when AC is first connected, then the LED will flash green once. The number of red flashes denotes the present curve (e.g. If the red flashes three times, it means the present curve is curve 3).
2. To choose another curve, please cut off the power supply first, then unpeel the label, pressing the button while connecting the power. If you want to choose curve 3,
release the button after the 3
rd
LED Flash. Now
the selected curve (e.g. curve 3) will be recorded in memory.
Alarms
LED Flashing Sequence
(
One Cycle
)
Indication
1
R G _ _ _ _ _ _
Wrong Battery
2
R G R _ _ _ _ _
Overcharged
3
R G R G _ _ _ _
Battery
Overheated
4
R G R G R _ _ _
Incorrect AC Input Voltage
5
R G R G R G _ _
External Thermal Sensor Fault
6
R G R G R G R _
Communication Interface Fault
7
G R _ _ _ _ _ _
Charger Overheated
8
G R G _ _ _ _ _
Charger Relay Fault
;
Repair
9
G R G R _ _ _ _
Charger Fault; Repair
Note:
1. R—red G—green
2. “_” denotes one second stop
3. Above LED flashing sequence is one cycle, the LED will flash repeatedly when in fault
.
Installation & Safety Instructions
1.
Preferably the charger should be installed in the horizontal position or installed vertically along radiation tooth. A space of 5cm around the radiation tooth should be open to ensure airflow.
2.
Ensure all heat dissipating parts are not obstructed to avoid overheating. Do not put the battery charger near any heat sources. Make sure that free space around the charger is enough to provide adequate ventilation & easy cable socket access.
3.
Ensure the consistency between the
alternating supply voltage and the allowable voltage input of the charger, p
lease approach a retailer or local Power Utility for enquiry.
4.
For safety and electromagnetic compatibility
,
the battery charger has a 3-prong plug that
apply to
the socket with
grounded outlet.
5. If you are using an extension cord
for al
ternating current power supply,
make sure that
it is affordable to the
maximum input current.
6. The voltage-drop between the charger and connection wire of the battery should be as less than 1% of the battery voltage as it can. Otherwise, it affects charging effect possibly. Meanwhile, the diameter of the wire should satisfy the output current value.
7
.
The thermal compensation probe for the battery voltage must be placed in the area of the highest battery temperature, such as between 2 batteries near the center of
the pack.
8. If the
charger does not work correctly or if it has been
damaged,
unplug it immediately from the supply socket, from the battery and contact a retailer.
9.
Do not try to service the charger yourself. Opening the cover may expose you to shock or other hazards.
10. To avoid damaging the power cord, do not put anything on it or place it where it will be walked on. If the cord becomes damaged or frayed, replace it immediately.